Cold Storage Roof Installation Melbourne VIC

EPSExpanded polystyrene is a frequent core in cold storage panels, and it is combustible
Hot workPoor control of it is a leading cause of fires in buildings with combustible panels
10 mOne insurer’s guidance bars hot work within this distance of EPS panels
Class 2 and 4The NCC 2022 condensation requirement F8P1 is written for these classes only

Cold storage roofing services in Melbourne

New roof installation

A new roof for a refrigerated or temperature-controlled building.

Replacement and re-roofing

Taking off a failing roof and fitting a new one. The permit, plumbing and asbestos checks on our home page apply here too.

Insulated roofing systems

Insulated roof panels for refrigerated buildings. The panel core matters, as the next section explains.

Repair and maintenance

Fixing leaks and damage, plus regular roof checks and upkeep.

Know the panel core before anyone cuts, drills or welds

Many cold storage buildings use insulated sandwich panels: two metal skins around an insulating core. Insurance guidance says expanded polystyrene (EPS) is frequently used as that core in food, beverage, pharmaceutical and cold storage buildings. The same guidance describes EPS as highly flammable. In a fire it gives off toxic smoke, and the panels delaminate and become structurally unstable.

That is why roof work on a cold store raises questions that an ordinary warehouse roof does not. Ask these before any work starts:

  • What is the panel core? QBE suggests signs on the panels that name the core type and warn against hot work nearby.
  • Will anything involve heat? Welding, grinding and similar work should be kept away from combustible panels, with repairs done by cold methods. Vero’s EPS guidance sets 10 m as the exclusion distance.
  • Is there a work permit system? QBE and Aon both recommend permits for work on insulated panels, recording what is being done, where, and by whom.
  • Is any core exposed, or any penetration unsealed? Vero advises sealing exposed polystyrene using cold work methods and running cables through conduit.
  • What does the building’s insurer require for replacement panels? QBE describes policies that require insurer-approved panels for all repairs and replacements.

If a panel’s core is exposed, say so before work starts. Insurer guidance treats damage that exposes the core as a fire risk in its own right, not only a leak. Tell the building’s manager and insurer first, so the repair method is agreed in advance.

Commercial roofing

Where the code ends and guidance begins

Not everything said about cold store roofs is a legal requirement. This is how the main points split.

Topic Status What it says
Hot work near combustible panels Insurer risk guidance, not legislation Vero, QBE and Aon recommend keeping hot work away from combustible panels, using cold work methods for repairs, and running a permit system. Your own insurer’s conditions come first.
Condensation NCC 2022 The condensation performance requirement F8P1 applies only to sole-occupancy units in Class 2 buildings and Class 4 parts, according to Victorian Building Authority training slides. It does not name cold stores, so ask the designer and building surveyor how condensation is being handled for your building, and check the current NCC wording.
Permits, roof plumbing, asbestos, heights Victorian rules These apply to any commercial roof job. They are explained once on the home page.

Related roofing pages

Cold storage often sits inside wider distribution and logistics sites. See our pages on distribution centre roofing, logistics facility roof installation and warehouse roof installation, or commercial metal roofing for the roof sheeting side.

Questions about cold store roof work

Do EPS panels have to be replaced?

Insurer guidance doesn’t give one fixed answer, so it is a question for the building’s insurer and designer. The guidance generally says to repair damaged panels promptly, seal any exposed polystyrene using cold work methods, and avoid installing more EPS panel. QBE describes policies that require insurer-approved panels for future repairs and replacements, so ask your insurer what it requires before choosing replacement panels.

What is the difference between hot work and cold work on insulated panels?

Hot work produces heat or sparks, such as welding, grinding and cutting with heat. Cold work uses methods that don’t, for example cold cutting when making openings for cables and pipes. Insurer guidance says to keep hot work away from combustible panels and use cold work for repairs. The distances vary. One insurer sets 10 m for EPS panels, so check what your own insurer requires.

What should I have ready before I call about a cold store roof?

The building address, what the roof panels are made of if you know, including any label naming the core, and where the leak or damage is. Add anything your insurer requires for panel work, and any hot or cold work permit rules the site already has.

Talk to us about your cold storage roof

Call 1300 941 905 or send the form with the building address, the panel type if you know it, and what is going wrong.

Call Now