Zincalume Commercial Roof Installation Melbourne VIC

UnpaintedZincalume gives roofing a traditional unpainted finish, unlike prepainted Colorbond
6-monthlyBlueScope’s minimum for hosing down areas not washed by rain, and more often where there is industrial fallout or salt
Light industrialBlueScope says Zincalume suits light industrial environments, and to contact it where there is heavy fallout, acid or alkali-laden air or corrosive chemicals
1 kmBlueScope’s guidance says full warranties may not apply within 1 km of salt water or heavy industrial activity unless suitable materials are chosen

Zincalume commercial roofing services

New Zincalume roofs

Roofing for new commercial buildings, planned around plant, skylights and drainage.

Replacement and re-roofing

Removing an ageing roof and fitting a new one. Work through the permit, plumbing and asbestos checks on our home page first.

Long-span roofing

See our commercial metal roofing and steel commercial roof pages for profiles and coatings.

Roof maintenance

Regular roof checks, hosing down of unwashed areas, fastener checks and gutter clearing.

Emergency repair

Stopping leaks and making a roof safe after storm or sudden damage, then planning a permanent fix.

Industrial buildings

See our industrial roofing page for factories, warehouses and plants.

Where Zincalume suits, and where it doesn’t

These come from BlueScope’s published guidance. Product details differ, so ask for the document that applies to your roof.

Point What the sources say What to do
Industrial environments BlueScope says Zincalume and Colorbond steel suit light industrial environments, but where the roof is exposed to heavy fallout, acid or alkali-laden air or other corrosive chemicals, it says to contact BlueScope for advice on a suitable product. Its Colorbond Ultra guidance adds that within 1 km of salt or brackish water, or of industrial activity causing heavy dust, chemical exposure, emission fallout, heat or moisture, full warranties may not apply unless suitable materials are chosen. Tell the roofer what the building and its neighbours emit, and ask whether the product has been confirmed with BlueScope for your site. Our Campbellfield page covers the checks in a heavy industrial estate.
Marine distance For salt marine influence only, BlueScope lists Zincalume and Colorbond steel as recommended for roofing more than 200 metres from breaking surf or exposed marine water, and more than 100 metres from calm marine water such as a harbour. If the site is near the bay, ask which product is recommended at that distance.
Washing BlueScope’s guidelines say areas not washed by rainwater should be hosed down at least every six months, and more often where there is industrial fallout or high salt concentrations. Ask which areas of the roof are unwashed, and who will wash them and when.
Compatibility BlueScope says to avoid galvanised gutters with Zincalume roofing, contact with lead, copper and copper-treated timber, brick-cleaning acid and touch-up paint, and that copper and lead flashings can drain corrosive run-off onto the roof. Ask which gutters, flashings, fasteners and fittings are specified, and whether any contain copper, lead or galvanised steel.
Removing an old roof In Victoria, non-friable asbestos can only be removed without a licence if the total is 10 square metres or less and the work takes under an hour in any seven-day period. Anything larger needs a licensed removalist. Ask for the asbestos register before a quote, because an old commercial roof is far larger than 10 square metres.

The old page said Zincalume resists corrosion in polluted urban environments, but BlueScope’s own guidance is more cautious. It suits light industrial sites, and says to consult BlueScope where there is heavy fallout or corrosive chemicals. I could not verify the old page’s claims about reflectivity, fire resistance or a 35-year life, so ask your roofer to confirm the product choice for your site in writing. A roof replacement is a bigger job than a like-for-like repair, so ask the council whether it needs a permit before you book.

Commercial roofer installing metal panels

Things to check before a Zincalume roof job

  • Whether the building or its neighbours produce heavy fallout, acid or alkali-laden air or corrosive chemicals, and whether BlueScope has been consulted.
  • How far the site is from salt water such as the bay or a harbour.
  • Which areas of the roof, such as under eaves and behind parapets, are not washed by rain, and who will wash them.
  • That no copper, lead, galvanised gutters or copper-treated timber touch the roof or drain water onto it.
  • The asbestos register for the building you are re-roofing, and test results for any suspect sheeting.
  • Who designs and certifies the box gutters, sumps and overflows.

Before you book Zincalume roof work

  1. Look the address up on VicPlan for the zone, flood overlays and any heritage or precinct controls.
  2. Ask the council whether a replacement or any added plant needs a permit.
  3. Ask for a written scope that names the product, the flashings and fasteners, and the asbestos and drainage arrangements.
  4. Work through the permit, plumbing and asbestos checks on the home page.

Questions about Zincalume commercial roofing

Is Zincalume suitable for a factory in a heavy industrial area?

Not automatically. BlueScope says Zincalume and Colorbond steel suit light industrial environments, but where the roof is exposed to heavy fallout, acid or alkali-laden air or corrosive chemicals, it says to contact BlueScope for advice. Tell the roofer what the site and its neighbours emit, and ask for the product choice to be confirmed in writing.

Does a Zincalume roof need washing?

Parts of it do. BlueScope’s guidelines say areas not washed by rainwater should be hosed down at least every six months, and more often where there is industrial fallout or high salt concentrations. Ask which parts of your roof are unwashed.

Can I touch up a scratch or cut edge on a Zincalume roof with paint?

BlueScope’s guidelines say to avoid touch-up paint on Colorbond and Zincalume roofing. Ask your roofer how scratches and cut edges will be handled, and what the manufacturer’s guidance says for your product.

What should I have ready before I call about a Zincalume commercial roof?

The building address, what the roof is made of, and what is going wrong. Add what the building and its neighbours emit, how close the site is to salt water, any rooftop plant or solar, any ponding or leaking box gutters you have seen, any warranty documents, and any asbestos register or test results you hold.

Talk to us about your Zincalume commercial roof

Call 1300 941 905 or send the form with the building address, the roof type and what is going wrong.

Call Now